Texto descriptivo  (Paragraph) This is a request for aid to support activities carried out by research groups in the Principality of Asturias during 2018-2019 on a competitive basis. The suggested challenges by the Lemur research group for the 2018-2020 trienium are aimed at consolidating current lines of research, relating to the integral management of electrical energy systems and at incorporating new research lines already started. Thus, among the lines in which the group has forged its trajectory the following ones must be highligted: Implementation of new power converter topologies for the integration distributed resources into the network. Development of distributed control systems for the integration of distributed resources in electrical networks and micogrids. Generalization of algorithms for the calculation of load flows for real time applications in DC/AC hybrid networks.

Agency: (Paragraph)
Investigator: (Paragraph)
Amount: (Paragraph)
Date: (Paragraph)

 

TÍTULO DE CATEGORÍA (H2)

SUBTÍTULO DE CATEGORÍA (H3)

Texto descriptivo  (Paragraph) This is a request for aid to support activities carried out by research groups in the Principality of Asturias during 2018-2019 on a competitive basis. The suggested challenges by the Lemur research group for the 2018-2020 trienium are aimed at consolidating current lines of research, relating to the integral management of electrical energy systems and at incorporating new research lines already started. Thus, among the lines in which the group has forged its trajectory the following ones must be highligted: Implementation of new power converter topologies for the integration distributed resources into the network. Development of distributed control systems for the integration of distributed resources in electrical networks and micogrids. Generalization of algorithms for the calculation of load flows for real time applications in DC/AC hybrid networks.

Agency: (Paragraph)
Investigator: (Paragraph)
Amount: (Paragraph)
Date: (Paragraph)

 

CAJA (TEXTO ACORDEÓN)

Arboleya, P., Coto, M., Gonzalez-Moran, C., Arregui, R., “On board accumulator model for power flow studies in DC traction networks” Electric Power Systems Research, Volume 116, November 2014, Pages 266-275, ISSN 0378-7796

Arboleya, P., Gonzalez-Moran, C., Coto, M., “Modeling FACTS for power flow purposes: A common framework” International Journal of Electrical Power & Energy Systems, Volume 63, December 2014, Pages 293-301, ISSN 0142-0615

Arboleya, P., Gonzalez-Moran, C., Coto, M., “Unbalanced Power Flow in Distribution Systems With Embedded Transformers Using the Complex Theory in alpha-beta-0 Stationary Reference Frame,” Power Systems, IEEE Transactions on , (Early Access) vol.PP, no.99, pp.1,11 doi: 10.1109/TPWRS.2013.2292112

Coto, M., Arboleya, P., Gonzalez-Moran, C., “Optimization approach to unified AC/DC power flow applied to traction systems with catenary voltage constraints” International Journal of Electrical Power & Energy Systems, Volume 53, December 2013, Pages 434-441

Alvarez, E., Campos, AM., Arboleya, P., Gutierrez, AJ. “Microgrid managementwith a quick response optimization algorithm for active power dispatch” (2012) International Journal of Electrical Power & Energy Systems, 43 (1), pp. 465-473.

Arboleya, P., Diaz, G., Coto, M. “Unified AC/DC Power Flow for Traction Systems:A New Concept” (2012) Vehicular Technology, IEEE Transactions on, vol. 61, no. 6, pp. 2421-2430.

Arboleya, P., Coto, M., Gonzalez-Moran, C., Reigosa, D.D. “A semiconductor H-bridge connection to avoid saturation in current transformers for differential protection” (2011) Electric Power Systems Research, 84 (1), pp. 120-127.

Arboleya, P., Diaz, D., Guerrero, J.M., Garcia, P., Briz, F., Gonzalez-Moran, C., Gomez Aleixandre, J. “An improved control scheme based in droop characteristic for microgrid converters” (2010) Electric Power Systems Research, 80 (10), pp. 1215-1221.

Díaz, G., González-Morán, C., Arboleya, P., Gómez-Aleixandre, J. “Characterization of flux rotation and of the ensuing core losses in the stator of induction motors” (2008) IEEE Transactions on Energy Conversion, 23 (1), pp. 34-41.

Diaz, G.; Gonzalez-Moran, C.; Arboleya, P.; Gomez-Aleixandre, J.; , “Analytical Interpretation and Quantification of Rotational Losses in Stator Cores of Induction Motors,”Magnetics, IEEE Transactions on , vol.43, no.10, pp.3861-3867, Oct. 2007

Diaz, G.; Arboleya, P.; Gonzalez-Moran, C.; Gomez-Aleixandre, J.; , “Revision of the hysteresis and excess loss computation method as a means of improving the rotational loss estimate in induction motors,” Electric Power Applications, IET , vol.1, no.1, pp.75-81, January 2007

Díaz, G., Arboleya, P., González-Morán, C., Gómez-Aleixandre, J. “Decomposition of fault currents in power transformers into suitable sets of components for application to fault characterization and modelling. Part 1: Theory” (2007) Electric Power Systems Research, 77 (3-4), pp. 328-338.

Diaz, G.; Arboleya, P.; Gomez-Aleixandre, J.; , “Analytical approach to internal fault simulation in power transformers based on fault-related incremental currents,” Power Delivery, IEEE Transactions on , vol.21, no.1, pp. 142- 149, Jan. 2006

Arboleya, P., Díaz, G., Gómez-Aleixandre, J., González-Morán, C. “A solution to the dilemma inrush/fault in transformer differential relaying using MRA and wavelets” (2006) Electric Power Components and Systems, 34 (3), pp. 285-301.

Díaz, G., Díaz, I., Arboleya, P., Gómez-Aleixandre, J. “A novel transformer protection technique and its performance assessment using self-organizing maps” (2006) Engineering Intelligent Systems, 14 (2), pp. 89-97.

Díaz, G., Blanco, I.D., Arboleya, P., Gómez-Aleixandre, J. “Zero-sequence-based relaying technique for protecting power transformers and its performance assessment using unsupervised learning ANN” (2006) European Transactions on Electrical Power, 16 (2), pp. 147-160.

Díaz, G., Arboleya, P., Gómez-Aleixandre, J. “Tracking space-vector plot asymmetries in transformer differential relaying” (2005) COMPEL – The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, 24 (3), pp. 1023-1040.

Díaz, G., Arboleya, P., Gómez-Aleixandre, J., De Abajo, N. “An algorithm using a shape-based approach in Park’s plane for transformer differential relaying on the basis of time-dependent symmetrical components” (2005) Electric Power Systems Research, 73 (3), pp. 295-303.

Díaz, G., Arboleya, P., Gómez-Aleixandre, J. “Multiwinding transformer protection applying the delta-relaying concept” (2005) Electric Power Components and Systems, 33 (2), pp. 199-211.

Díaz, G., Arboleya, P., Gómez-Aleixandre, J. “A new transformer differential protection approach on the basis of space-vectors examination” (2005) Electrical Engineering, 87 (3), pp. 129-135.

Diaz, G.; Arboleya, P.; Gomez-Aleixandre, J.; , “Park-based and zero sequence-based relaying techniques with application to transformers protection,” Generation, Transmission and Distribution, IEE Proceedings- , vol.151, no.5, pp. 619- 624, 13 Sept. 2004

González, G.D., Fernández, J.G.-A., AArboleya, P. “Electromagnetic model of turn-to-turn short circuits in transformers” (2004) COMPEL – The International Journal for Computation and Mathematics in Electrical and Electronic Engineering, 23 (2), pp. 558-571.

González, G.D., Fernández, J.G.-A., Arboleya, P. “Diagnosis of a turn-to-turn short circuit in power transformers by means of zero sequence current analysis” (2004) Electric Power Systems Research, 69 (2-3), pp. 321-329.